Layout - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the size of the spool ID enclosure.

Specifying a mixture of new line and blank character indicators that are used by the software to pad-out the Style setting effectively increases the size of the enclosure. The size of the text, which is controlled by the Text Size setting, that is displayed within any increased size enclosure is not increased in size. The data string associated with each identifier consists of a combination of the @, $, and ? characters.

  • The @ character signals a blank (space) requirement.

  • The $ character signals a new line requirement.

  • The ? character indicates where the actual data from the declared record should be located in the 'padded-out' record.

Setting the value to the text string @$@@?@@$@ increases the Style with the diamond-end enclosure as shown in the example below:

Use the increase in size with care as it affects the isometric representation considerably.

Defines:

Option Switch - N/A
I-Configure - Drawing.Format.SpoolIDEnclosureStyle