Pointed Layout - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the physical size of the pointed-ended enclosure used to contain user input messages. This is achieved by specifying a mixture of new line and blank character indicators that instruct the software to pad-out the normal message record to effectively increase the size of the enclosure. The data string associated with each identifier consists of a combination of @, $, and ? characters.

  • The @ character signals a blank (empty space) requirement.

  • The $ character signals a new line requirement.

  • The ? character indicates where the actual data from the declared record is to be located in the padded-out record.

Type the data string in the box. For example, typing @@?@@ enlarges the message enclosure as shown in the example.

MessagePointEnclosure

Defines:

Option Switch - N/A
I-Configure - Drawing.Format.MessagePointedEnclosure

The size of the text does not increase, only the size of the enclosure.