Length - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the number of characters output for a weld number. For numeric weld numbers, leading zeros are output; for alphabetic weld numbers, spaces are output.

  • Variable outputs the weld number without leading zeros or spaces.

  • 1 to 9 sets the number of characters to be output. For example, 3 outputs 001 through 999 for numeric weld numbers.

Defines:

Option Switch - 53, Pos 9
I-Configure - Drawing.Welds.WeldNumberLength