Type - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the type of material list that Isogen outputs on the isometric drawing.

  • Normal suppresses creation of special type of material list

  • Special gives every item a separate entry except gaskets and bolts, which are accumulated. Isogen assigns a U prefix to pulled bends, and assigns a W or B prefix to welds.

  • Normal with alpha pointers creates a regular material list. However, Isogen uses an alpha system of material list pointers (A, B, C...) instead of the default numeric system.

Defines:

Option Switch - 23, Pos 2
I-Configure - MaterialList.FixedLayout.MLType