Edit the Dimensional Parameter in the User Defined Part Class Sheet - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Reference Data

Language
English
Product
Intergraph Smart 3D
Subproduct
Reference Data
Search by Category
Reference Data
Smart 3D Version
11 (2016)

The Dimensional Parameter is not used to create the unique ID definition of the record. Therefore, you can mark the existing record as modified by typing M at the beginning of the record. However, because the valve operator is an output to the symbol definition of the valve, you must mark all affected valve part records as modified by typing M character at the beginning of each record.

  1. Open the User Defined Part Class sheet.

  2. Locate the record, edit the Dimensional Parameter value, and then type M at the beginning of the record.

  3. In the Part Classes sheets, locate the valve parts affected by the changes.

  4. At the beginning of each affected valve part record, type M.

  5. Bulkload the spreadsheet, and review the log file.

  6. Use Catalog Checker to review the impact of the proposed changes.

  7. Because editing the Dimensional Parameter impacts the modeled objects, use Synchronize Model with Catalog to mark the out-of-date objects.

  8. Use Synchronize Workspace to update the objects.

  9. Verify your changes, and resolve any discrepancies.

Use a SQL statement to find all affected valves. For more information, see Edit the Valve Operator Part Number in the Piping Commodity Material Control Data Sheet.