Permissible Tap Rule - Intergraph Smart Reference Data - Version 10.0 - Training - Hexagon

Intergraph Smart Reference Data Training (2020)

Language
English
Product
Intergraph Smart Reference Data
Search by Category
Training
Smart Materials/Smart Reference Data Version
2020 (10.0)

In this section, we will learn how to create the permissible taps rule for the specified specification.

  1. Open Integration > Smart 3D > Smart 3D Configuration.

  2. Go to Templates tab.

  3. Expand TRAINING_TEMPLATE from the tree view. Double-click PermissibleTaps sheet to open the grid view.

    • Set the default tap for a 1” NPD

    • Place a 3000# socket weld tap when NPD is between 0.75” – 4”

    • Place a hole circular end tap when NPD is between 6” – 24”

      Permissible Tap Rule 1

      The Permissible Tap Numbers are defined in TapProperties rule.

      Permissible Tap Rule 2

  4. Save the changes and lock the grid.

  5. Go to Integration > Smart3D > Smart3D Transfer Jobs.

  6. Create a New Run of the export job CC150-1 and start the job.