Connect to a Project Schema - Intergraph Smart Instrumentation - 13.1 - Administration & Configuration - Intergraph Process, Power & Marine Documentation

Intergraph Smart Instrumentation Configuration and Maintenance Guide (2019)

PPMProduct
Intergraph Smart Instrumentation
PPMCategory_custom
Administration & Configuration
Version_SPI_custom
13.1
  1. On the menu bar, click File > Database Type Test and Query.

  2. Connect to the Domain schema.

  3. In the Query pane, type following command:
    select * from ENGINEERING_PROJECT;

  4. Click Execute.

  5. On the SQL Result window, scroll right to display the Eng Log Name and Eng Log Pass columns.

    The Eng Log Name and Eng Log Pass columns contain Project and As- Built schema logon information.  The Engineer Name column displays names of existing projects.

  6. Type the target Project schema logon name, which appears in the Eng Log Name column, in the Schema logon name box in the Database Type Test and Query window.

  7. Type the target Project schema logon password, which appears in the Eng Log Pass column, in the Schema logon password box in the Database Type Test and Query window.

  8. Do one of the following:

    • Click Actions > Connect.

    • Click .

The Results pane displays the result of the connection.  A zero (0) indicates a successful operation.  Codes that indicate a connection failure include a message explaining the reason for the failure.

See Also

Smart Instrumentation Database Schemas