Appendix: Material Control report title block entries - Intergraph Smart 3D - Help

Intergraph Smart 3D Isogen Isometric Drawings

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Help
SPFVersion_custom
2019 (10.0)
Version_S3D
12.x(2018)
Version_IConfig
6.0(2016)
Version_ICP
2.0(2016)
Version_ISOGEN
13.0(2016)

The following table contains the pipeline attributes and calculated values that you can define for the Material Control report title block. For information about including a title block in the report, see Include Title Block in Report options.

Strings enclosed in single quotes (') in the PCF and IDF columns are equivalent. For example, 'AREA' produces the same ouput as '-10' in the report title block: the value of the pipeline attribute AREA.

Pipeline Attribute

PCF

IDF

AREA

'AREA'

'-10'

NUMBER-OF-DRAWINGS

'NUMBER-OF-DRAWINGS'

'-703'

PIPELINE-REFERENCE

'PIPELINE-REFERENCE'

'-6'

REVISION

'REVISION'

'-8'

PROJECT-IDENTIFIER

'PROJECT-IDENTIFIER'

'-9'

BATCH

'BATCH'

'-10'

PIPING-SPEC

'PIPING-SPEC'

'-11

NOMINAL-CLASS

'NOMINAL-CLASS'

'-12'

NOMINAL-RATING

'NOMINAL-RATING'

'-12'

DATE-DMY

'DATE-DMY'

'-14'

INSULATION-SPEC

'INSULATION-SPEC'

'-15'

TRACING-SPEC

'TRACING-SPEC'

'-16'

PAINTING-SPEC

'PAINTING-SPEC'

'-17'

PIPELINE-TEMP

'PIPELINE-TEMP'

'-18'

SURFACE-AREA

'SURFACE-AREA'

'-738'

MAXIMUM-N.S.

'MAXIMUM-N.S.

SYSTEM-REFERENCE

'SYSTEM-REFERENCE'

'-25'

NUMBER-OF-SPOOLS

'NUMBER-OF-SPOOLS'

'-763'

EQUIPMENT-TRIM-
REFERENCE

'EQUIPMENT-TRIM-
REFERENCE'

'-29'

WELD-DIAMETERS

'WELD-DIAMETERS'

'-731'

WELD-DIAMETERS-
FABRICATION

'WELD-DIAMETERS-
FABRICATION'

'-759'

WELD-DIAMETERS-
ERECTION

'WELD-DIAMETERS-
ERECTION

'-760'

WELD-DIAMETERS-
OFFSHORE

'WELD-DIAMETERS-
OFFSHORE'

'-761'

WELD-DIAMETERS-PIPE

'WELD-DIAMETERS-PIPE

'-776'

WELD-DIAMETERS-
SUPPORT

'WELD-DIAMETERS-
SUPPOT

'-777'

MISC-SPEC1

'MISC-SPEC1'

'-41'

MISC-SPEC2

'MISC-SPEC2'

'-42'

MISC-SPEC3

'MISC-SPEC3'

'-43'

MISC-SPEC4

'MISC-SPEC4'

'-44'

MISC-SPEC5

'MISC-SPEC5'

'-45'

CLEANING-REQUIREMENT

'CLEANING-REQUIREMENT'

'-1100'

PAINT-COLOUR

'PAINT-COLOUR'

'-1101'

CONSTRUCTION-TYPE

'CONSTRUCTION-TYPE'

'-1102'

DESIGN-PACKAGE

'DESIGN-PACKAGE'

'-1103'

DESIGN-TEMPERATURE

'DESIGN-TEMPERATURE'

'-1104'

ENGINEERING-WORK-
PACKAGE

'ENGINEERING-WORK-
PACKAGE'

'-1105'

INSTALLATION-WORK-
PACKAGE

'INSTALLATION-WORK-
PACKAGE'

'-1106'

FLUID-CODE

'FLUID-CODE'

'-1107'

HANDOVER-SYSTEM-ID

'HANDOVER-SYSTEM-ID'

'-1108'

TRACING-REQUIREMENT

'TRACING-REQUIREMENT'

'-1109'

TEST-PRESSURE

'TEST-PRESSURE'

'-1110'

INSULATION-THICKNESS

'INSULATION-THICKNESS'

'-1111'

MAIN-NS

'MAIN-NS'

'-1112'

OPERATING-PRESSURE

'OPERATING-PRESSURE'

'-1113'

OPERATING-TEMPERATURE

'OPERATING-TEMPERATURE'

'-1114'

PID-DRAWING-NUMBER

'PID-DRAWING-NUMBER'

'-1115'

LINE-ID

'LINE-ID'

'-1116'

ALT-DESIGN-PRESSURE

'ALT-DESIGN-PRESSURE'

'-1117'

ALT-DESIGN-TEMPERATURE

'ALT-DESIGN-TEMPERATURE'

'-1118'

DESIGN-CODE

'DESIGN-CODE'

'-1119'

FLUID-PHASE

'FLUID-PHASE'

'-1120'

FROM

'FROM'

'-1121'

HANDOVER-SUBSYSTEM-ID

'HANDOVER-SUBSYSTEM-ID'

'-1122'

NDT-REQUIREMENT

'NDT-REQUIREMENT'

'-1124'

PID-REVISION

'PID-REVISION'

'-1125'

PROCUREMENT-WORK-
PACKAGE

'PROCUREMENT-WORK-
PACKAGE'

'-1126'

STRESS-CATEGORY

'STRESS-CATEGORY'

'-1127'

STRESS-PACKAGE

'STRESS-PACKAGE'

'-1128'

TEST-MEDIUM

'TEST-MEDIUM;

'-1129'

TO

'TO'

'-1130'

PWHT-REQUIREMENT

'PWHT-REQUIREMENT'

'-1131'

SEQUENCE-NUMBER

'SEQUENCE-NUMBER'

'-1132'

CONSTRUCTION-WORK-
PACKAGE

'CONSTRUCTION-WORK-
PACKAGE'

'-1134'

ATTRIBUTE0-
ATTRIBUTE199

'ATTRIBUTEn'

'-600:-699'
'-900:-999'