  1. In the Domain Explorer, click the Hook-Ups folder to displays all hook-up types and hook-ups.

  2. Select (hold the CTRL key and click the items) the Flow and Valves hook-up types and then, on the shortcut menu, click Actions > Associate with Instrument Types.

  3. On the Associate Hook-Up Types with Instrument Types dialog box, select instrument type FE – D/P Type Flow Element.

  4. Do one of the following to associate the instrument type with the Flow hook-up type:

    • Click Associate.

    • Drag the FE – D/P Type Flow Element instrument type to the Associated instrument types pane.

  5. In the same way, associate instrument type FT – D/P Type Flow Transmitter with the Flow hook-up type.

    The Associated instrument types pane should appear as shown:

  6. Click Next.

  7. Associate instrument type FV – CONTROL VALVE with the Valves hook-up type.

  8. Click OK.