Press F8 to open the Reference Explorer.
-
Click the Panels folder.
-
Right-click the Junction Boxes folder, and on the shortcut menu, click New > Junction Box (Generic).
-
On the Junction Box Properties dialog box, type the panel name as follows. 16 INSTRUMENTS WITH I/S.
-
Click OK.
-
To view the new junction box in the Reference Explorer, double-click the Junction Boxes folder to expand it.
-
To add a terminal strip, right-click the new junction box and on the shortcut menu, click New > Terminal Strip.
-
On the Terminal Strip Configuration dialog box, click New.
-
On the Number of Terminals in Pattern dialog box, type 3 and click OK.
-
Define the configuration of the new terminal strip, in the Configuration name field, and the Terminal Numbering Pattern, as shown.
-
Click Save to save the configuration, then click Create to create the terminal strip.
-
On the Terminal Strip Properties (New) dialog box, click in the Terminal strip field and name the terminal strip 16 inst+ind. shield and then click OK.