Connect to the Domain Schema on Oracle - Intergraph Smart Instrumentation - Help - Intergraph Process, Power & Marine Documentation

Intergraph Smart Instrumentation Internal Setup

PPMProductFamily
Engineering and Schematics
PPMProduct
Intergraph Smart Instrumentation
PPMCategory
Help
Version_SPI_custom
2018 (12.0)
  1. On the menu bar, click File > Database Type Test and Query.

  2. Under Database type, do the following:

    • Select Oracle.

    • In the ODBC driver box, enter the DBMS parameter of your Oracle version.

  3. Under Connection settings, do the following:

    • In the Schema logon name box, enter the target Domain schema logon name specified by the System Administrator when initializing the domain.

    • In the Schema logon password box, enter the target Domain schema logon password specified by the System Administrator when initializing the domain.

  4. In the Server name and Database name boxes, enter the Oracle instance alias name, which is the same for the Oracle server name and Oracle database name.

  5. Do one of the following:

    • Click Actions > Connect.

    • Click .

The Results pane displays the result of the connection.  A zero (0) indicates a successful operation.  Codes that indicate a connection failure include a message explaining the reason for the failure.

See Also

Checking Database Version Compatibility
Smart Instrumentation Database Schemas