The connection between the Plate System being detailed and one of its boundaries is missing. Detailed parts cannot be generated on this system. - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_S3D
12.x(2018)

Meaning: The connection between the Plate System being detailed and one of its boundaries is missing. Detailed parts cannot be generated on this system. A Connection between the Plate System and its boundary has been deleted or a bounding object either needs to be updated or no longer touches the bounded object.

Recovery:

  1. Verify that the boundaries are not on the To Do List and require updating.

  2. After updating the boundaries, perform a re-compute on this object.

  3. If unrepairable, report the steps taken to your support group.