Meaning: The equipment's weight and center of gravity could not be computed because one or more of the components that define the equipment do not have the weight or center of gravity values defined for them.

Recovery:

  1. Set the Locate Filter to Equipment Component.

  2. Select each of the equipment components that define the designed equipment.

  3. Click Edit > Properties.

  4. On the Occurrence tab, select Weight and CG from the Category drop down.

  5. Verify that the weight and center of gravity values are defined.

  6. Click OK.