Feature could not be generated, please revise the projection values for adjacent turn features - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
12 (2018)

Meaning: Because the previous and next straight features of a trench run overlap, Smart 3D could not create the trench turn feature between the straight features.

Recovery:

  1. In the Workspace Explorer, select the trench turn feature that is in error.

  2. Click Properties .

  3. The Trench Turn Feature Properties dialog box displays.

  4. On the General tab, select Dimensions in the Category box.

  5. Change the projection values so that the inside lengths of the previous and next straight runs do not overlap.

  6. Click OK.

  7. Click Finish on the command ribbon.

-OR-

  1. In the Workspace Explorer, select the trench run that is in error.

  2. Click Path .

  3. Increase the lengths of the Sketch 3D segments so that the previous and next straight runs do not overlap.

  4. Click Finish on the path ribbon, and then click Finish on the command ribbon.