The foundation port graphics cannot be created with given circular holes information. The graphics of the foundation port is invalid. Ensure that number of holes and bolt hole diameter values are correct in order to create proper graphics of the foundati - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Administration & Configuration
Version_S3D
12.x(2018)

Meaning: The number of holes and the bolt hole diameter values defined for the foundation port are not valid or exceed the boundaries of the foundation. Because of this, Smart 3D cannot generate the foundation graphics.

Recovery: Edit the hole definitions so that the holes fit within the foundation boundaries.