Meaning: Collinear members connected with a splice connection must have the same rotation and mirror value. One member was placed with a different rotation/mirror value or modified to have different values.
Recovery: Edit both collinear members to make their rotation and mirror values the same.
-
Open the Structure task.
-
Click Select .
-
Set the Locate Filter to Member Parts.
-
Select one of the members.
-
Note the Angle and Reflect settings on the ribbon.
-
Select the other member and define the same Angle and Reflect settings for it.