12

Specifies the node number increment used to step from Start Node to Stop Node for in a group of restraints that is loaded by this spectrum for Independent Support Motion analysis (ISM). The spectrum is applied to all restraint nodes in the group between Start Node and Stop Node in steps of Increment. The range of nodes must include at least one node in the piping system. If no value is entered, the load is applied at the start node.

This option is only available when Earthquake (spectrum) is selected for Analysis Type.