A Flanged Plate exists without the start or end points defined - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12 (2018)

Message

A Flanged Plate exists without the start points defined.

Or

A Flanged Plate exists without the end points defined.

Severity

Crucial.

Detailed Description

A Plate (Bracket) associated to a Flanged Plate Active Entity and a symbol is missing the relationship to the start or end points.

Possible Cause

Possible causes include:

  • Symbol inputs not correctly defined.

  • Transaction aborted during definition of the Flanged Plate.

  • Unknown.

Possible Impacts

The flange will not be processed, and errors may occur.

What You Should Do

  1. Verify that the symbol being used is properly defined.

  2. Modify the plate being flanged by redefining the symbol or attempting a recomputation.

  3. Re-run the DB Integrity check.

  4. If the problem still exists and the plate is as expected (needed), report the situation to Smart 3D Support. Revisions may be necessary.