A Design- or Planning-split operation without a seam does not have one result - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12 (2018)

Message

A Design- or Planning-split operation without a seam does not have one result.

Severity

Fatal.

Detailed Description

A Design split operation or Planning split operation does not have one seam, indicating that there is no split to be performed. In such cases, the split operation (AE) should have one and only one geometry as a result.

Possible Causes

Unknown.

Possible Impacts

Improper part development.

What You Should Do

  1. Open the model.

  2. In the Molded Forms task, select the object, and modify it, if necessary. Or, select the object, and perform a re-computation to update it.

  3. Re-run the Check Database Integrity custom command and the DBIntegrity report.

  4. If the object is still posted, contact Smart 3D Support.