The Logical Connection does not have the user class set - Intergraph Smart 3D - Administration & Configuration

Intergraph Smart 3D Database Integrity Administration

Language
English
Product
Intergraph Smart 3D
Subproduct
Database Integrity
Search by Category
Administration & Configuration
Smart 3D Version
12 (2018)

Message

The Logical Connection does not have the user class set.

Severity

Fatal.

Detailed Description

The logical connection has not had the proper user class set by the system.

Possible Cause

Unknown.

Possible Impacts

The Logical Connection will not be updated properly.

What You Should Do

  1. Ask your database administrator to back up the model.

  2. Supply all information possible that may have led to this situation, and submit this information along with the backup to Smart 3D Support.

  3. Delete the object using one of the following methods:

    • Select the object in the Workspace Explorer, and delete it.

    • Run the Clean Database custom command to delete the object.

  4. Re-create the Logical Connection by using the Place Logical Connection command.