Message
The center flange is missing a connection to the pipe part.
Severity
Crucial.
Detailed Description
To allow a fitting placed by Hole Management to be spooled, a connection must exist between the pipe part and the fitting. The center flange of the hole in error is missing the connection to the pipe part that allows it to be spooled along with the pipe part.
Possible Cause
The hole may have been created in an older version of the software, and the migration command failed to create the connection.
Possible Impacts
If the connection does not exist, then the center flange cannot be spooled with the pipe part.
What You Should Do
-
Open the model.
-
Run the HoleMgmt V6 middle tier migration command (HMV6Migration.HoleFittingPartsMigration).
This command updates the older objects with the new relationship.