Define Component Insulation Exclusion - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Reference Data

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Reference Data
Version_SThreeD_Custom
12.1 (2019)
  1. Open the InsulationData.xls workbook.

  2. Select the ComponentInsulationExclusion sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Piping Commodity Type column, type the codelist number for the piping commodity for which you are defining the rule.

  5. In the First Size From column, specify the beginning first size for the range.

  6. In the First Size To column, specify the ending first size for the range.

  7. In the First Size Units column, specify the units.

  8. In the Heat Tracing Medium column, specify the heat tracing medium codelist number.

  9. In the Insulation Purpose column, specify the insulation purpose codelist number.

  10. Type the insulation temperature range.

  11. Save the InsulationData.xls workbook, and bulkload it into the catalog.

See Also

Component Insulation Exclusion