Edit the Flange Thickness in the Piping Generic Data Bolted Sheet - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Reference Data

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Reference Data
Version_S3D
12.1(2019)

The Flange Thickness in the Piping Generic Data Bolted sheet is not used to create the unique ID definition of the record. Therefore, you can mark the existing record as modified by typing M at the beginning of the record. For example, the correct flange thickness for 1.25 inch size, 125# pressure rating, flat-face flanged end is 0.5 inches based on the ASME B16.5 standard.

  1. Open the Piping Generic Data Bolted sheet.

  2. Locate the record, edit the Flange Thickness value, and then type M at the beginning of the record.

  3. Bulkload the spreadsheet, and review the log file.

  4. Because editing the Flange Thickness impacts the modeled objects, use Synchronize Model with Catalog to mark the out-of-date objects.

  5. Use Synchronize Workspace to update the objects.

  6. Verify your changes, and resolve any discrepancies.