Port Details - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Reference Data
Version_S3D
12.x(2018)

For the standard type and ring type there are two ports: Route and RodEnd.

For the J Hanger type, there are three ports: Route, RodEnd, and Surface.

In the J Hanger configuration, both the Route port and the RodEnd port retain their orientation. The Surface port’s X-axis is aligned along the side of the band. Its XY plane is flush with the surface of the band.

Port1 – Route

In order to be able to connect easily to a pipe, the X-axis of the Route port goes through the opening of the ring. The Z-axis points towards the RodEnd port.

Port Type

Size

MinSize

MaxSize

1016 - Pipe Clamp

Pipe Outside Diameter

Pipe Outside Diameter

Pipe Outside Diameter

Port2 – RodEnd

Port Type

Size

MinSize

MaxSize

1011 - IntThdRH

Diameter of the rod for connecting to other components

Rod Diameter

Rod Diameter

1011 - IntThdLH

Optional Port3 – Structure (0, -PipeOD/2 – 2*Thickness2 – Thickness1, Height4)

Port Type

Size

MinSize

MaxSize

1011 - Steel

-1

9999

9999