Port Details - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
12 (2018)

These properties are used to specify the different port types and their sizes for the yoke clamp.

Port1 – Route (0, 0, 0)

PortType

Size

MinSize

MaxSize

1016 - Pipe Clamp

Diameter1

Diameter1

Diameter1

Port2 – Pin (0, 0, RodTakeOut)

If hsPinOrLug = 1 then

PortType

Size

MinSize

MaxSize

1005 - Pin

Pin1Diameter

Pin1Diameter

Pin1Diameter

If hsPinOrLug = 2 then

PortType

Size

MinSize

MaxSize

1008 - Single Lug

Length4

Zero

Pin1Diameter