Neutral Input File Locations dialog box - Intergraph I-Convert - Help - Hexagon

Smart Isometrics I-Convert Help

Language
English
Product
Intergraph I-Convert
Search by Category
Help
I-Convert Version
8.0(2019)

Specification directory

Specifies the name of the project name folder, which contains the data files to be processed. This field is mandatory.

Data schema file

Specifies the schema .xml file, which is located in the Dat folder in the project. This field is mandatory.

SKEY Redefinition file

In I-Convert, certain SKEY’s trigger special actions. For example a PB (pulled bend) triggers the software to not generate any catalog items as these are not required in the Smart Isometrics catalog. An RE** (eccentric reducer) triggers the calculation of an offset. An NBSC (barrel nipple) SKEY triggers the software to use the modifier column to determine the length. If you have any redefined SKEYs, these actions will not function. Therefore, you can specify an SKEY Redefinition file. This file lists the new SKEY together with an SKEY to which it is be mapped.This field is optional. For more information, see SKEY Redefinition file.

To avoid entering every user-defined SKEY in the SkeyUser.tbl , mapping the SKEY to a standard Isogen SKEY causes I-Convert to deal with the component as a standard component.

OK

Accepts all changes and closes the dialog box.

Cancel

Cancels all changes and closes the dialog box.

Apply

Accepts all changes without closing the dialog box.

Defaults

Resets all settings in the dialog box to the stored defaults.

Help

Opens the online documentation displays the Help-related topic.