Indicates the in-plane stress intensification factors (SIFs) for a bend or an intersection.
Specify this value for any point in the piping system by selecting the SIFs & Tees check box on the Classic Piping Input dialog box. Type the node number to which the stress applies. Then, specify the In-Plane SIF (ii) value on the SIFs/Tees tab.
-
For more information on stress intensification factors (SIFs), see Stress Intensification Factors and Stress Indices Details.
-
For more information on using local coordinate systems to define in-plane and out-plane, see Tee Elements and Stress Intensification Factors (SIFs) in CAESAR II Local Coordinate Definitions.
-
If you do not specify a value in the In-Plane SIF (ii) and Out-Plane SIF (io) boxes, the software performs code-related calculations.