Opens the PCF Mapping dialog box, where you define .pcf mapping for the software. With this utility, you can:

  • Change the mapping of PCF keywords to CAESAR II attributes.

  • Change the keyword names.

  • Add new keywords.

  • Create new attributes, such as cladding thickness, cladding density, and additional temperatures and pressures.

You can achieve the best results by preparing customized mapping before beginning the import process.

Save

Saves the mapping to the PCF_MAP.XML file in the System folder.

Open System Folder

Opens the C:\ProgramData\Intergraph CAS\CAESAR II\11.00\System folder. From here, you can open other .pcf mapping files in a text editor to manually change mapping.

PCF Unit Mapping

PCF Material Mapping

PCF Restraint Mapping

PCF Stress Intensification Factor Mapping

Reset Mappings

Changes the mapping template. Select Stress ISO or Super PCF. Stress ISO is the default value.

Full Text Search

Searches the CAESAR II Attribute and PCF Keyword columns.

Stress ISO Mapping

Defines custom attributes in the component-attribute<n> format supported by Intergraph Smart 3D.

CAESAR II Attribute

PCF Keyword

Pressure 1 (design pressure)

COMPONENT-ATTRIBUTE1

Temperature 1 (maximum temperature)

COMPONENT-ATTRIBUTE2

Material

COMPONENT-ATTRIBUTE3

Wall Thickness (reducing thickness in the case of reducing components)

COMPONENT-ATTRIBUTE4

Insulation Thickness

COMPONENT-ATTRIBUTE5

Insulation Density

COMPONENT-ATTRIBUTE6

Corrosion Allowance

COMPONENT-ATTRIBUTE7

Fluid Density

COMPONENT-ATTRIBUTE9

Hydro Test Pressure

COMPONENT-ATTRIBUTE10

Line Number

PIPELINE-REFERENCE

Super PCF Mapping

CAESAR II Attribute

PCF Keyword

Pressure 1

DESIGN-PRESSURE

Pressure 2

ALT-DESIGN-PRESSURE

Pressure 3

OPERATING-PRESSURE

Temperature 1

DESIGN-TEMPERATURE

Temperature 2

ALT-DESIGN-TEMPERATURE

Temperature 3

OPERATING-TEMPERATURE

Insulation Thickness

INSULATION-THICKNESS

Fluid Density

SPECIFIC-GRAVITY

Hydro Test Pressure

TEST-PRESSURE

Line Number

PIPELINE-REFERENCE

Units

The units associated with the values of these attributes are defined by including a descriptive unit label after the value. For example, the pressure attribute, COMPONENT-ATTRIBUTE1, can be specified as COMPONENT-ATTRIBUTE1 15.3 barg.

If the unit label chosen (such as barg) is not one of the labels recognized by the software, as defined through Utilities > Tools > Create/Review Units on the main window ribbon, then you must include that label in the PCF_UNITS_MAP.TXT file in the System folder. For more information, see Create/Review Units and PCF Unit Mapping.