Pressure Index (Ip) - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Indicates the sustained pressure index (Ip).

Specify this value for any point in the piping system by selecting the SIFs & Tees check box on the Classic Piping Input dialog box. Type the node number to which the stress index applies. Then, specify the Pressure Index (ip) value on the SIFs/Tees tab.

If you do not specify a value in the Pressure Index (Ip) box, CAESAR II sets the value to 1.0 by default.

For more information on stress intensification factors (SIFs) in CAESAR II, see Stress Intensification Factors Details.