Include Piping Input Files - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Piping Input menu: Environment > Include Piping Input Files

Import Model toolbar: Include piping files

Includes other piping models in the current piping model. Piping models added may have a node offset applied and can optionally be rotated about the Y-axis before being added.

Include Piping Files Dialog Box

File Name

Displays the file to include. Click Browse to browse for the file name. The file need not reside in the current data directory.

Read Now

Specifies whether the file is read immediately. Select Y if the file is to be read immediately and stored as part of the current input. The file read may be edited as part of the current job. Select N, if the file is to be read for plotting and fully processed only during error checking. The file read may not be edited as part of the current job.

RotY

Specifies the angle about the Y axis to rotate the model before including it in the current job. The rotation applies regardless of the Read Now setting.

You can also rotate the model from the List utility. For more information, see Rotate.

Inc

Specifies the increment to be added to all nodes in the model before including it in the current job. The node increment applies regardless of the Read Now setting.