Specifies temperature and pressure values. Use this table to define the flange Temperature-Pressure rating as a function of temperature for a material grade. You can type up to 24 temperature-pressure pairs. These values must be typed in ascending temperature order.
Pressure - Typical units (depending on your unit system):
-
lb/in²
-
Bar
-
KPa
-
MPa
Temperature - Typical units (depending on your unit system):
-
ºF
-
ºC
Flange evaluation is based on a specific load case temperature. To evaluate the flanges in a model, specify the operating temperature at which the software evaluates the flanges in the Flange Analysis Temperature box on the Load Cases tab of the Static Analysis - Load Case Editor.