Specifies the weld identifier value. Choose from the following options:

  • 0 or BLANK - As Welded

  • 1 - Finished/Ground Flush

This box is only applicable for:

  • IGE/TD/12

  • Bonney Forge Sweepolets

  • Bonney Forge Insert Weldolets

  • Butt Welds in the Swedish Piping Codes or the IGE/TD/12 code

If you specify a value of 1 - Finished/Ground Flush, then the software considers the weld to be ground flush on the inside and out and it calculates the SIF as 1.0.