Comparison Method - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Specifies the method used to compare the actual nozzle loads to the defined limits. Available choices are:

Absolute

Each load is compared directly to the corresponding limit. That is, FX to FX_allowable, FY to FY_allowable, and so on.

|Fa| £ |Fal|

|Fb| £ |Fbl|

|Fc| £ |Fcl|

|Ma| £ |Mal|

|Mb| £ |Mbl|

|Mc| £ |Mcl|

SRSS

The square root sum of the squares (SRSS) of each load divided by the corresponding allowable is compared to 1.0.

Forces

and

Moments

Unity Check

The sum of the three forces and three moments, each divided by their respective allowables is compared to 1.0.

and