Nominal Thickness for this P Number <or> P Number Thickness - CAESAR II - Help

CAESAR II Users Guide

Language
Русский
Product
CAESAR II
Search by Category
Help
CAESAR II Version
12

Enter the thickness for the P number.

Table UCS-57 of the ASME Code, Section VIII, Division 1 lists the maximum thickness above which full radiography is required for welded seams. This thickness is based on the P number for the material listed in the allowable stress tables of the Code.

If a seam is partially radiographed and the required thickness exceeds the P number thickness, <aProduct> automatically changes the joint efficiency to 1.0 as stated in the Code.