Place Manual Chamfer - Intergraph Smart 3D - Help

Intergraph Smart 3D Structural Detailing

PPMProduct
Intergraph Smart 3D
PPMCategory_custom
Help
Version_SThreeD_Custom
10.1 (2014 R1)

Creates a manual chamfer between two detailed parts. This command supports creation of a chamfer between the following part types:

  • Detailed plate parts

  • Standard member parts

  • Detailed edge reinforcements

  • Any combination of the previous parts

Place Manual Chamfer Ribbon

Controls options for placing a chamfer between two detailed part ports. The parts do not have to be connected.

Properties

Displays the Chamfer Properties dialog box, which you use to view and modify the properties of the chamfer before it is written to the database. For more information, see Chamfer Properties Dialog Box.

Chamfer Method
Displays images corresponding to supported methods for creating a manual chamfer.

  • Bounded Plate Chamfer - Initiates chamfer creation by selecting part, face, and face.

  • Unbounded Plate Chamfer - Initiates chamfer creation by selecting part and face.

  • Edge Reinforcement Chamfer - Initiates chamfer selection by selecting an edge reinforcement part and face.

Select Parent Part

Select the part that contains the first port to use in creating the chamfer. This part is the parent of the chamfer.

Select Port to be connected from Parent Part

Specifies a port from the parent part. This port is used as the first input to the chamfer for bounded or unbounded chamfers.

Select Other Port to connect to

Specifies a port from another part that overlaps the port from the parent part. This port is not required for an unbounded chamfer.

Select Port on End Cut

Specifies a port on the Edge Reinforcement end cut of the chamfer.

Finish

Creates the chamfer.

Chamfer Class

Specifies the chamfer root class for the chamfer.

Chamfer Item

Specifies the chamfer.

Rule Based

Enables or disables the Chamfer Item list. Selecting this check box disables the Chamfer Item list.

Extension Type

Allows you to select the length options for a chamfer. Select Overlap, Full Edge, or Extend by Value.

  • Extension 1 - Specifies the start of the extension length. This option is available only when Extend by Value is selected.

  • Extension 2 - Specifies the end of the extension length. This option is available only when Extend by Value is selected.

What do you want to do?