If you move a pipe run in working state connected to another pipe run in non-working state, the software disconnects them. The software retains the base parts at the connection, and deletes the mating parts and associated connections in working state. If a mating part or a connection is in non-working state or at a different satellite location, the software generates a To Do Record (TDR). To complete the disconnection you must update the corresponding TDR. You can only update the TDR if you have Write access on the object.

If moving a selection is restricted by adjacent features, use Disconnect to disconnect that selection, and then use Move to move the selection without disturbing the rest of the network. For more information, see Disconnect.

See Also

Pipe run to pipe run connections

Header to branch connections

Equipment to pipe run connections