These properties are optional. Enter values for these properties to have a row of top bolts to use with split, clamp-type straps. These bolts are at the specified offset from the top of the pipe and are also centered on the top extensions.

IJUAhsPin2::Pin2Diameter (Optional)

Specifies the pin diameter of the bolt. All bolts are drawn with the same diameter. If Pin2Diameter is set to zero, then the bolts are not drawn.

IJUAhsPin2::Pin2Length (Optional)

Specifies the length of the bolt. All bolts are drawn with the same length, starting at Offset2 above the bottom of the strap. If Pin1Length is set to zero, then the bolts are not drawn.

IJUAhsOffset3::Offset3 (Optional)

Specifies the offset of the bolt centerline from the top surface of the pipe.

IJUAhsMulti2::Multi2Qty (Optional)

Specifies the quantity of bolts. Bolts are not shown on the strap when Multi1Qty is set to zero. Valid cases are shown in the example below..

IJUAhsMulti2::Multi2LocateBy (Optional)

Specifies the location of the bolts. Each bolt can be located in two ways.

1 - Relative to center of the group
2 - Relative to edge.

The exact meaning depends on the quantity of bolts. This value can be 0 (nothing), 1 (center), or 2 (Edge).

IJUAhsMulti2::Multi2Location (Optional)

Specifies the distance for exact location of the bolts depending on Multi1LocateBy and Multi1Qty. This value can be either a distance to the edge or a center-to-center spacing. Valid cases are shown in the example below.