Basic Clamp Properties - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
12.1 (2019)

These properties define the geometry of the pipe clamp body.

For these properties, the default unit of distance is "mm". Specify "in" at the end of the dimensional value to use inches (for example 10in).

IJUAhsDiameter1::Diameter1

Specifies the inside diameter of the pipe clamp body. It is the same as the outside diameter of the pipe.

IJUAhsThickness1::Thickness1

Specifies the thickness of stock, which is used to make the pipe clamp body. It also specifies the thickness of the top and bottom tabs.

IJUAhsInsulationThickness::InsulationThickness

Specifies the insulation thickness of the stock, which is used to make the pipe clamp body.

IJUAhsWidth1::Width1

Specifies the width of the clamp body. In general, both the left and right halves of the clamp are of the same width, unless Width2 is specified. If Width1 is negative, the left half of the clamp is not displayed. Width1 cannot be zero or undefined.

IJUAhsWidth2::Width2

Specifies the second width of the clamp body. It is the optional width. Both halves of the clamp are of the same width if Width2 is zero. Both halves of the clamp are of different widths if Width2 is specified with a reasonable value. The right half of the clamp is not shown if Width2 is negative. Width2 is ignored when Angle1 is set to 360-degrees.

IJUAhsHeight1::Height1

Specifies the height from pipe center to top of clamp. The value of Height1 cannot be zero or less than the outside diameter of the clamp body.

IJUAhsHeight2::Height2

Specifies the height from pipe center to the bottom of the clamp. The value of Height2 cannot be zero or less than the outside diameter of clamp body. It is ignored when Angle1 is set to 360-degrees.

IJUAhsGap1::Gap1

Specifies the gap between the two top tabs. This value is always greater than or equal to zero.

IJUAhsGap2::Gap2

Specifies the gap between the two bottom tabs. This value is always greater than or equal to zero. It is ignored when Angle1 is set to 360-degrees.

IJUAhsAngle1::Angle1

Specifies the sweep angle between the top and bottom tabs. When Angle1 is set to 360-degrees, only the left half of the clamp is displayed and Gap1 is used for the tab space. In this case, the pipe clamp looks like this: