IJUAhsThickness2::Thickness2 (optional)

Specifies the thickness of the upper curved plate. If Thickness2 is less than or equal to zero, then the upper plate is not drawn.

IJUAhsLength2::Length2 (optional)

Specifies the length of the upper plate. If Thickness2 is greater than zero, then Length2 is greater than or equal to zero.

IJUAhsAngle3::Angle3 (optional)

Specifies the angle from the vertical center line of the pipe to the left edge of the top plate. Either Angle3 and Angle4, or Width3 and Width4, can define the sweep of the plate. Angle3 and Angle4 take precedence. If Thickness2 is greater than zero, then either (Angle3 and Angle4) or (Width3 and Width4) is greater than zero.

Angle3 <= 180 degrees – Angle1

IJUAhsAngle4::Angle4 (optional)

Specifies the angle from the vertical center line of the pipe to the right edge of the top plate. Either Angle3 and Angle4, or Width3 and Width4, can define the sweep of the plate. Angle3 and Angle4 take precedence.

If Thickness2 is greater than zero, then either (Angle3 and Angle4) or (Width3 and Width4) is greater than zero.

Angle4 <= 180 degrees – Angle2

IJUAhsWidth3::Width3

Specifies the distance from the vertical center line of the pipe to the left inside edge of the top plate. The curved plate is only drawn on the upper half of the pipe. Angle3 and Angle4 must be zero or this is ignored. Width3 must be less than 0.5 * PipeOD.

IJUAhsWidth4::Width4

Specifies the distance from the vertical center line of the pipe to the right inside edge of the top plate. The curved plate is only drawn on the upper half of the pipe. Angle3 and Angle4 must be zero or this is ignored. Width4 must be less than 0.5 * PipeOD.