Quick Route Cableway Ribbon - Intergraph Smart 3D - Help

Intergraph Smart 3D Electrical

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Help
Version_S3D
12.x(2018)

Join From

Specifies the starting end point.

Join To

Specifies the terminating end point.

Path Options

Displays all possible route path options to join the two end points. The first path option displayed on the menu is the default option.

The software always computes the paths along the active co-ordinate axes.

  • Join Direct - Joins the from and to end points directly with a one-segment run, irrespective of the axes.

  • XY - Joins the from and to end points with the first segment run along the X-axis (E-axis), and then with the second segment along the Y-axis (N-axis).

  • YX - Joins the from and to end points with the first segment run along the Y-axis, and then with the second segment along the X-axis.

  • YZ - Joins the from and to end points with the first segment run along the Y-axis, and then with the second segment along the Z-axis (El-axis).

  • ZY - Joins the from and to end points with the first segment run along the Z-axis, and then with the second segment along the Y-axis.

  • XZ - Joins the from and to end points with the first segment run along the X-axis, and then with the second segment along the Z-axis.

  • ZX - Joins the from and to end points with the first segment run along the Z-axis, and then with the second segment along the X-axis.

  • X-YZ - Joins the from and to end points with the first segment run along the X-axis, and then with the second segment along the YZ plane.

  • Y-ZX - Joins the from and to end points with the first segment run along the Y-axis, and then with the second segment along the ZX plane.

  • Z-XY - Joins the from and to end points with the first segment run along the Z-axis, and then with the second segment along the XY plane.

  • YZ-X - Joins the from and to end points with the first segment run along the YZ plane, and then with the second segment along the X-axis.

  • ZX-Y - Joins the from and to end points with the first segment run along the ZX plane, and then with the second segment along the Y-axis.

  • XY-Z - Joins the from and to end points with the first segment run along the XY plane, and then with the second segment along the Z-axis.

  • XYZ - Joins the from and to end points with the first segment run along the X-axis, the second segment run along the Y-axis, and the third segment run along the Z-axis.

  • XZY - Joins the from and to end points with the first segment run along the X-axis, the second segment run along the Z-axis, and the third segment run along the Y-axis.

  • YZX - Joins the from and to end points with the first segment run along the Y-axis, the second segment run along the Z-axis, and the third segment run along the X-axis.

  • YXZ - Joins the from and to end points with the first segment run along the Y-axis, the second segment run along the X-axis, and the third segment run along the Z-axis.

  • ZXY - Joins the from and to end points with the first segment run along the Z-axis, the second segment run along the X-axis, and the third segment run along the Y-axis.

  • ZYX - Joins the from and to end points with the first segment run along the Z-axis, the second segment run along the Y-axis, and the third segment run along the X-axis.

Finish

Places a run along the selected route path.

Run

Displays the existing cableways in the model along with the <New Cableway>, <New/Continue Run>, <Select Graphically>, <Load More Runs>, and More options. Select the run to route.

<New Cableway> displays the New Cableway dialog box. Use this option to create a new cableway run.

<New/Continue Run> extends an existing cableway if you select the end feature of that cableway. If a run is continued, all runs associated with the system parent of the continued run display in the list. If you do not select an end feature, the New Cableway dialog box is displayed to create a cableway. For more information, see New Cableway Dialog Box.

<Select Graphically> allows you to select an existing run in a graphic view, or the Workspace Explorer.

<Load More Runs> loads all the runs that belong to the parent system. This option is not available after you load all the runs, or if the parent system contains less than 200 runs.

More displays the Select Cableway dialog box. Use this option to select a cableway that is associated with a different system parent. For more information, see Select Cableway Dialog Box.

Fast Compute

Specifies whether the software must render complete computed graphics.