Define Reinforcing Pad Widths - Intergraph Smart 3D - Help

Intergraph Smart 3D Catalog

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Help
Version_S3D
12.1(2019)
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Reinforcing Pad Data.

  3. Click Insert Row to insert a blank row in the grid view.

  4. In the Header Size column, specify the header size for the pad width that you are defining.

  5. In the Branch Size column, specify the branch size for the pad width that you are defining.

  6. Define the angle range for the pad width that you are defining.

  7. In the Minimum Reinforcing Pad Width column, enter the minimum reinforcing pad width.

  • For more information about each reinforcing pad data property that you can define, refer to Reinforcing Pad Data.

  • The Reinforcing Pad Data sheet in the Piping Materials Class.xls workbook corresponds to the Reinforcing Pad Data node. For more information about the Piping workbooks delivered with the software, see Piping Reference Data.