Define Field Fit Length - Intergraph Smart 3D - Help

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
12.1 (2019)
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Field Fit Length Rule.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Construction Requirements End 1 column, type the construction requirement codelist value for end 1.

  5. In the Construction Requirements End 2 column, type the construction codelist value for end 2.

  6. In the Field Fit Length column, type the field fit length to use when computing the cut length of plain piping for the defined weld type, diameter, and construction requirements.

  7. In the Nominal Piping Diameter From column, type the lower boundary for nominal pipe diameter.

  8. In the Nominal Piping Diameter To column, type the upper boundary for nominal pipe diameter.

  9. In the Nominal Piping Diameter Units column, type the units for the NPD. For example, type mm or in.

  10. In the Weld Class column, enter the weld class for which to define a field fit length.

  11. In the Weld Type column, enter the weld type code for which to define a field fit length.

.The Field Fit Length sheet in the workbook corresponds to the Field Fit Length Rule node in the Catalog task. See Piping Reference Data.