  1. Open the Piping Specification.xls workbook.

  2. Select the ServiceLimits sheet.

  3. Select a row after the Start keyword but before the End keyword, and click Insert > Row.

  4. In the Spec Name column, type the name of the piping materials class.

  5. In the Temperature column, type the temperature service limit.

  6. In the Pressure column, type the pressure service limit.

  7. Save the Piping Specification.xls workbook.

The piping materials class must be defined on the PipingMaterialsClassData sheet.

See Also