The output engineering properties are calculated and populated by the software based on the information provided by the input properties.
IJUAhsInstalledLoad::InstalledLoad
Specifies the load on the spring at the installed condition. This load is commonly referred to as the cold load. The following calculation is used to find the installed load value:
IJUAhsVariability::Variability
Specifies the percentage difference between Operating and Installed loads.
IJUAhsInstalledTravel::InstalledTravel
Specifies the total spring travel at the installed load with respect to the working range.
IJUAhsOperatingTravel::OperatingTravel
Specifies the total spring travel at the operating load with respect to the working range.
IJUAhsInstalledRodTakeOut::InstalledRodTakeOut
Specifies the calculated rod takeout at the installed load. This value is used by Type A, B, C, and G springs. Alternatively, this value is the rod takeout that is used when modeling the spring and determining port positions.
IJUAhsInstalledRodAddIn::InstalledRodAddIn
Specifies the calculated rod add-in at the installed load, and is used by Type D and E springs. Alternatively, this value is the rod add-in that is used when modeling the spring and determining port positions.
IJUAhsInstalledHeight::InstalledHeight
Specifies the calculated ColumnHeight at the installed load, and is used by Type F springs. Alternatively, this value is the height that is used when modeling the spring and determining port positions.