Output Engineering Properties - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D Hangers and Supports SmartParts Configuration

Language
English
Product
Intergraph Smart 3D
Subproduct
3D Symbols
Search by Category
Reference Data
Smart 3D Version
11 (2016)

The output engineering properties are calculated and populated by the software based on the information provided by the input properties.

IJUAhsInstalledLoad::InstalledLoad

Specifies the load on the spring at the installed condition. This load is commonly referred to as the cold load. The following calculation is used to find the installed load value:

IJUAhsVariability::Variability

Specifies the percentage difference between Operating and Installed loads.

IJUAhsInstalledTravel::InstalledTravel

Specifies the total spring travel at the installed load with respect to the working range.

IJUAhsOperatingTravel::OperatingTravel

Specifies the total spring travel at the operating load with respect to the working range.

IJUAhsInstalledRodTakeOut::InstalledRodTakeOut

Specifies the calculated rod takeout at the installed load. This value is used by Type A, B, C, and G springs. Alternatively, this value is the rod takeout that is used when modeling the spring and determining port positions.

IJUAhsInstalledRodAddIn::InstalledRodAddIn

Specifies the calculated rod add-in at the installed load, and is used by Type D and E springs. Alternatively, this value is the rod add-in that is used when modeling the spring and determining port positions.

IJUAhsInstalledHeight::InstalledHeight

Specifies the calculated ColumnHeight at the installed load, and is used by Type F springs. Alternatively, this value is the height that is used when modeling the spring and determining port positions.