Define Collar Inputs - Intergraph Smart 3D - Reference Data

Intergraph Smart 3D 2D Symbols

Language
English
Product
Intergraph Smart 3D
Subproduct
2D Symbols
Search by Category
Reference Data
Smart 3D Version
11 (2016)
  1. On the Collar Symbols toolbar, click Add Input Properties .

    The Name Graphic Inputs dialog box displays. The profile group, slot group, and base plane curve group are now defined as input for the collar.

  2. In the graphics window, click on the slot group. The row in the Graphics Inputs grid associated with this group highlights.

  3. In the Attribute Name field, select Name.

  4. In the Value field, type Slot.

  5. Click Apply.

  6. Click OK.

Stiffener and base plate inputs should already be defined from copying the slot and profile groups from the slot symbol file into the collar symbol file. If not, see Define Slot Inputs.