We recommend that you use the same ISOGEN options for both internal and external extractions. This method reduces the risk of inconsistent isometric settings between the two extractions. If you make the line ID unique by adding a 'J' suffix to the line sequence number, then this will be enough to separate the two parts of the jacket system using the same line ID format. However, when the project dictates that the two lines, internal and external, are of different line ID formats, separate ISOGEN options files, identified by separate Intergraph default sets should be used.

See Also

Modeling Jacketed Piping
Jacketed Piping