This object is not synchronized with the catalog (All Tasks) - Intergraph Smart 3D - Administration

Intergraph Smart 3D Troubleshooting Reference

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Administration
Version_S3D
12.x(2018)

This object is not synchronized with the catalog (All Tasks)

Meaning: The Synchronize Model with Catalog command in Project Management was run while the object was read-only. The object was read-only either because the Status was set to something other than Working, or the user who ran the synchronization did not have write permission to the object.

Recovery: If the cause was the object having a status not set to working:

  1. Select the object in error.

  2. Change the Status of the object to Working.

  3. Start Project Management.

  4. Click Tools > Synchronize Model with Catalog.

  5. Alternatively, click View > To Do List.

  6. On the To Do List dialog box, select the object, and click Update .

    The software updates the object and removes it from the To Do List.

If the cause was the user not having write permission to the object:

  1. Start Project Management as a user with write access to the object.

  2. Click Tools > Synchronize Model with Catalog.

  3. If you have a global workshare configuration, run Synchronize Model with Catalog at each location.