Could not retrieve the References Argument from the symbol (Structural Detailing)

Meaning: The software failed to retrieve the part's symbol references arguments that provide the parameters; therefore, the software failed to create or modify a smart part (bracket, pad, collar, or parametric).

Recovery: Verify that the symbol exists and is properly defined. Verify none of the inputs are on the To Do List. Make any necessary corrections. If problem still exists, report steps taken to your support group.