Message
Member part has more than one attached cross section definition.
Severity
Normal.
Detailed Description
Every part has an indirect relationship to its cross section definition in the catalog that provides the basic properties of the section. If a part has more than one related definition, it is ambiguous as to which cross section definition to use.
Possible Cause
Unknown.
Possible Impacts
Most likely, the properties of the member part cannot be reviewed.
What You Should Do
Remove the offending member part.
-
Ask your database administrator to back up the model.
-
Supply all information possible that might have led to this situation, and submit this information along with the backup to Hexagon PPM Support.
-
Open the model.
-
Select the offending member part, and delete it.