StructContinuity type/priority not being set on a Root System - Intergraph Smart 3D - Administration

Intergraph Smart 3D Database Integrity Administration

PPMProductFamily
3D Design and Visualization
PPMProduct
Intergraph Smart 3D
PPMCategory
Administration
Version_S3D
11.x(2016)

Message

StructContinuity type/priority not being set on a Root System.

Severity

Crucial.

Detailed Description

The Structural Continuity for Ship Type (Continuous, Intercostal) or its priority is not set on a Root Plate, Stiffener, or Edge Reinforcement System.

Possible Cause

Unknown.

Possible Impacts

Plates and Stiffeners may fail during processing, especially in Struct Detailing where the Rules are used. The Physical Connections for profiles penetrating plates would be the prime problem.

What You Should Do

  1. Select the Root System, and edit the Ship type on the property page.

  2. Re-run the Check Database Integrity custom command to verify that this error has been fixed.